[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index] RE: Misting air-con Quattro V8
Many thanks to those peopel who reply to my posting and emailed me directly about the problem with misting up in my V8 Quattro. Pretty well everyone said the behing the air recirculation flap I would find a broken spring that meant the flap wasn't closing. So at the weekend I pulled out the glove box (what do you call that in the US?), and checked around behind the flap - sure enough, broken spring! (And also a little condesate water lying in there.) I've re-fashioned a hook on the broken end and replaced it (MUCH easier said than done). At normal settings, the flap stays closed unless I press the Recirc button, so all seems to be working as it should, but I've noticed is that on full a/c (ie with temp set to LOW) the system opens the recirc flap anyway - I guess this is in an attempt to get maximum speed of cooling by recirculating the air until the temperature is up a bit. I can now only wait in hope that the misting is a thing of the past! Alex ---------- From: Alex Gray-OUPC To: Audi list Subject: Misting air-con Quattro V8 Date: 08 May 1998 16:50 Please, please, does anyone know how to cure occasional but serious steaming up of Quattro 200 and V8 interior. I'm not talking about the usual little flush of humidity when an a/c starts up, but a real pumping of humid air into the vehicle. A little background...
|